Phase Lab
English한국어

Phase margin

Example snubber bounds

2×CL and 3×CL are separate bounds. The resistor uses the entered snubber capacitor.

Worked example

RisoCsCL

Each block is its own estimate. They are not combined into one pass or fail.

Snubber capacitor, 2×CL

Snubber capacitor, 2×CL 2 nF

Equation

One snubber bound is 2*CL.

Snubber capacitor, 3×CL

Snubber capacitor, 3×CL 3 nF

Equation

Another snubber bound is 3*CL. It does not replace the 2*CL line.

Snubber resistor

Snubber resistor 28.8675 ohm

Equation

Snubber resistor is about Ro*sqrt(CL/(Cs+CL)).

Isolation zero

This estimate needs: isolation resistor.

Feedback capacitor from fc

This estimate needs: isolation resistor, crossover frequency fc.

Feedback capacitor from GBW/3

This estimate needs: isolation resistor.

Feedback capacitor from Rf

This estimate needs: isolation resistor.

Starting load example is 50 ohm and 1 nF. Phase margin stays blank until you enter fc and the phase at fc.